Lubrication


           Circulating oil lubrication system
           When using a circulating oil lubrication sys-
           tem with any SDAF housing, oil is introduced
           through the inlet holes in the housing cap and
           drained from one or both sides of the base.
            Drains should lead downward immediately
           outside of the housing to prevent oil from
           accumulating in the housing. Too high an oil
           level can result in higher operating tempera-
           tures due to churning of the lubricant. The
           drain pipes must be adequately sized and
           arranged to allow oil to drain from the housing.
           Additional considerations may be necessary
           when using a circulating oil system. These can
           include special housing seals, cross drilling the
           housing sump, wet sump requirements, flow
           rates, and drain hole dimensions. For more
           information, contact the SKF application engi-
           neering service.